Ventus Respiratory© TR2 - CE Certified

https://www.reconbrothers.com/web/image/product.template/2398/image_1920?unique=e468703
(0 review)

261.00 261.0 USD 261.00 CHF 275.00

CHF 254.39 CHF 275.00

Not Available For Sale

  • Color/Pattern
  • Brand

This combination does not exist.

Unfortunately this product is out of stock, however we can have it made. Read our "made to order policy" for production times, conditions & more info.

Color/Pattern: Black
Brand: Ventus Respiratory©

Terms and Conditions
Generally ​Ships the Same/Next Business Day

LUNG PROTECTION

Protect your respiratory system against harmful particulates that cause short or long-term illnesses.

KEEP PERFORMING

A very breathable system with minimal inhalation resistance allowing its use during strenuous activities.

LOW-PROFILE

TR2 is a comfortable low-profile respiratory solution that doesn't compromise shooting performance. 

UNIVERSAL FIT

Designed to fit a wide range of facial profiles (incl. facial hair) & compatible with other headborne equipment.

DESCRIPTION

The Ventus Respiratory© TR2 (Tactical Respirator 2) was developed in collaboration with Tier 1 operators. It provides a better means of lung protection while training/operating in compromised environments.

Today’s special operations forces understand the importance of protecting their respiratory system, but cannot afford to compromise their ability to perform effectively. This is the foundation upon which the TR2 was designed. By offering a low-profile solution that’s easy to don and integrates seamlessly with a variety of kit configurations, the TR2 is the most adaptable respirator for tactical units in Military and Law Enforcement as well as for First Responders available.

PRODUCT FEATURES

EFFICIENCY

  • Filters solid non-oil particulates including aerosolized lead, mold & fungal spores
  • Filters oil-based particulates
  • Single filter can be used multiple times
  • Simple filter replacement

BREATHABILITY

The TR2 is very breathable, even during strenuous activities and thus doesn't compromise the ability to perform as required.

COMPATIBILITY

  • Fits a wide range of facial profiles
  • Maintains seal with facial hair
  • Low riding seal is eyewear & NVG compatible
  • Can be worn with & without a helmet
  • Doesn't interfere with chin-strap

COMFORT

  • Low profile design minimizes cheek weld interference
  • Articulates when speaking to maintain seal
  • Downward-facing venting doesn't fog eyewear
  • Built-in flex zones allow for improved comfort & head articulation

PERFORMANCE

  • TR2 is CE 773281 certified
  • P2-02 filter is CE 773283 certified
    • ≥ 99% filtration efficiency for the sodium chloride filtration challenge for both single & multiple shift use
    • > 97% efficiency for the paraffin oil test & > 95% efficiency when retested after 24 hrs following the initial oil penetration challenge
    • Certified for multiple shift use (i.e. not restricted to single-use like other products in market)
    • Granted a P2 classification in accordance to EN 143:2021 (= filtration efficiency over > 94%) despite performing well above this minimum requirement
  • CE 773282 certification for the manufacture of respiratory protective equipment
  • Medical-grade silicone meets or exceeds ISO10993-5: 2009, ISO10993-10: 2010, ISO10993-10: 2019, ISO10993-11: 2017, ISO10993-4: 2017
  • Testing to be conducted in accordance with 42 CFR Part 84.182 and NIOSH standard procedure TEB-APR-STP-0004

MORE DETAILS

  • Weight: 145 g
  • Made in Canada
  • *NOTE: It is normal to still observe smell while using the TR2 respirator

IMPROVEMENTS COMPARED TO TR2 NON-CE VERSION

  • Improved filtration efficiency to > 99%
    • The CE-Certified P2-02 filter offers improved filtration efficiency compared to the previous TR2 filter.
    • Tests ≥ 99% filtration efficiency for the sodium chloride filtration challenge
  • 15% increased breathability
    • The P2-02 filter offers an approximately 15% improved (lower) inhalation resistance compared to the original TR2 filter. The original TR2 filter has an average inhalation resistance of 1.65 hPa (16.8 mmH2O) @ 85 LPM, while the P2-02 has an average inhalation resistance of 1.4 hPa (14.3 mmH2O) @ 95 LPM.
  • Approved for use against oil-based contaminants
    • The CE-Certified P2-02 filter is effective and approved for use against both solid (non-oil) particulates as well as oil-based particulates in accordance with the requirements of the EN143:2021 standard. The previous TR2 filter was developed to address solid (non-oil) particulates.

AVAILABLE ACCESSORIES

P2-02 FILTERS (3 PACK)

Replacement filters for the TR2 tactical respirator.

HELMET STRAP

The TR2 Helmet Strap has been designed to easily integrate the TR2 Respirator into multiple existing helmet rail systems.

MICROPHONE & CABLE

The TR2 comms integration provides extremely clear communications with compatibility into the most common systems.

IN THE BOX 

  • 1x TR2 - CE Certified
  • 1x Head harness
  • 1x Black MOLLE pouch + patch
  • 1x P2-02 Filter
  • 1x Manual

WHEN SHOULD I REPLACE MY P2-02 FILTER?

Useful life of any filter depends heavily on environmental and usage conditions. For example, filters used in less contaminated environments may offer longer service life than those used in heavily contaminated environments.

Excessive breathing resistance when inhaling indicates that the cartridge has served its useful life. Leave the contaminated area and replace the filter cartridge immediately. Cartridges should also be replaced when physically damaged or visibly soiled.

CAN THE P2-02 FILTER BE REUSED?

Yes, the P2-02 filter is approved for multiple shift use. In order to be certified for use in more than a single shift, filters are required to be tested against both salt (NaCl) and paraffin oil, stored for 24 hours, and then retested with the same challenge. The filter has passed all these tests.

DOES THE CE FILTER (P2-02) WORK

WITH THE NON-CE TR2?

The CE-Certified P2-02 filter cartridge is compatible with both the CE-Certified TR2 as well as the uncertified TR2. However, it is important to note that using the P2-02 filter with the Non-CE TR2 does not convert the respirator into a certified system; the facepiece of the respirator is required to hold its own certification to the EN140:1998 standard. Only the CE-Certified TR2 meets the requirements of this standard.

GUARANTEED
GENUINE PRODUCTS

WORLDWIDE
SHIPPING

FAST
CUSTOMER SERVICE

MADE TO ORDER PRODUCTS